Vibration:

  • Frequency; 1Hz to 5 kHz
  • Maximum samples; 16384
  • Amplitude Range; -20g to +20g acceleration
  • Sampling Frequency; 500 to 20k samples per second 
  • Resolution; 6400 lines

Temperature:

  • Internal sensor capability measurement; from -40 to 115 ºC (Accuracy +/-0.5ºC (0-60ºC), +/-1.5ºC (-40-115ºC))
  • Ambient temperature sensor limits; -20ºC to 60ºC operating, 10ºC to 25ºC storage

Other:

  • IP67 rated
  • Storage; typically 5000 readings
  • Case material; 316 Stainless Steel and Polycarbonate